Micro GC Fusion®
Analytical Excellence in Under 3 Minutes
Streamlined High-Speed Gas Analysis
The Micro GC Fusion® is a high-performance, miniaturized chromatography platform purpose-built for rapid gas analysis. Engineered for both real-time online process monitoring and versatile offline laboratory testing, it enables the high-speed characterization of complex gas mixtures. This compact and agile system allows you to effortlessly manage diverse sample matrices while maintaining uncompromising precision.
Micro GC Fusion®, Advanced Modular Chromatography
The Micro GC Fusion® is the industry benchmark for the rapid analysis of permanent gases and light hydrocarbons, such as natural gas and biogas.
While historically rooted in laboratory research, the Fusion has rapidly expanded into the most demanding industrial sectors thanks to its technological breakthroughs. Key innovations—specifically rapid temperature programming and a license-free, embedded web-based architecture—allow it to handle complex heavy-end compounds that were previously beyond the reach of micro-gas chromatography.
True Modularity for Customized Performance
What do we mean by modular?
The micro GC consists of analytical modules. A module is a full chromatograph: their combination defines the molecules that the analyser will be able to separate and detect.
Equipped with an integrated micro-sampling pump, the Fusion effortlessly interfaces with a vast array of sources—from gas bags and syringes to vials, high-pressure cylinders, or direct reactor coupling. This versatility provides a comprehensive ecosystem for your experimental protocols, ensuring reliable and representative analysis regardless of your sample container.
A New Era of Gas Chromatography: The Micro GC Fusion® Revolution
Driven by years of continuous innovation, the Micro GC Fusion® redefines the boundaries of micro-chromatography. It stands on three major technological pillars:
- High-Speed Temperature Programming: For unparalleled analytical performance and the ability to separate heavier compounds.
- Embedded License-Free Architecture: An on-board computer ensuring a rapid start-up and seamless integration with modern communication protocols.
- Linear Injector: A unique design achieving perfect linearity from low ppm to 100% concentration.
Operating Principle:
The Micro GC Fusion® operates on the fundamental principles of gas chromatography: separating mixture components for precise detection using a Universal µTCD (Thermal Conductivity Detector).
The system provides accurate quantitative data through external calibration.
The sample is either drawn by an internal pump or flows through the 1/16" inlet, where it is distributed across independent analytical modules working in parallel. This simultaneous processing generates a dedicated chromatogram for each module, culminating in a comprehensive analysis report that compiles all results in seconds.
Analysis time: 1 to 3 minutes
Chassis Options: 2-module or 4-module (Benchtop or Rackmount)
Detector: μTCD 2.0 (MEMS technology)
Detection range: <1 ppm to 100%
Options:
- Offline license
- Modbus TCP/IP option
- 4-20mA available via Analysis
- CHEMBOX
Why Choose the Fusion®?
– Unmatched Analytical Flexibility: Unlike traditional isothermal systems, our temperature programming allows a single module to operate across the entire working range of a column, significantly expanding your application scope.
– Optimized Sample Integrity: The entire sample path is temperature-regulated and inert to eliminate cold spots. This drastically improves the separation of reactive compounds (e.g., NH3) and challenging molecules like moisture (H2O).
– "No-Install" Software Philosophy: The control software is embedded directly into the analyzer. No licenses, no complex installations.
Accessible via any web browser on PC, tablet, or smartphone, it supports multi-user access—even during active analysis.
– It is designed according to the philosophy of an industrial automaton: robust, simple to use with only a few buttons, and offering a reliable to any test in an industrial environment.
– The Micro GC Fusion® has several types of injectors to achieve the best performance according to the applications, including the fixed volume injector. This unique injector is able to manage the analysis of complex matrices (binary matrix, ternary matrix, etc.) to obtain accurate and repeatable results.
Want to see our technology in action? Explore our library of application notes in the Documentation Tab to find a solution tailored to your specific industry.
Non-exhaustive list. Contact us for unlisted compounds.
| Modules | Analyzed Compounds |
| RT-Molsieve 5A | H2, He, O2, N2, CO, CH4, Ar, Xe, Kr |
| RT-Q Bond | CO2, hydrocarbons (C2-C6 and isomers C2-C3), light alcohols, H2S, H2O, NH3, N2O, SO2, etc. |
| RT-U Bond | CO2, Hydrocarbons (C2-C4 and isomer C2), H2S, COS, mercaptans, acetaldehyde, etc. |
| Stabilwax DB | BTEX (benzene, toluene, xylenes...) and polar compounds |
| Rxi-1ms | Hydrocarbons up to C12, VOCs |
| RT- Alumina | Hydrocarbons C2 to C6, olefins |
| CP-Sil 19CB | Mercaptans, SO2, THT |
| CP-Sil 13CB | Mercaptans, CS2, DMS, TBM |
Application Notes Micro GC Fusion:
- AN2018 001 MS5A O2 N2 CO2
- AN2018 002 – Trace N2 in O2 Ar – Fast trace analysis N2 in O2 /Ar
- AN2019 006- Micro GC Fusion® Sensitivity
- AN2019 002 Stability-of-measure-on-molecular-sieve-MS5A
- AN2019 012 Detection Neon Atmospheric
- AN2020 013 – BTEX siloxanes in biogas
- AN2021-015 – Xenon Analysis in Air
- AN2024-10 – Micro GC Ammonia application
See also:
Need a specific configuration? Our experts are here to help. Contact us!
The CHEMLYS Advantage: Total Support Ecosystem
High-Performance Accessories
Explore our curated selection of essential peripherals and consumables—everything you need to optimize and maintain your Micro GC Fusion® environment.
Tailored Service Agreements
Choose from flexible, multi-level support packages designed to ensure maximum uptime and peak performance, perfectly aligned with your operational requirements.
Training
Elevate your team's proficiency through our specialized gas chromatography programs. Gain the technical autonomy to master your analytical workflows and confidently adapt to future process evolutions.
Expertly Integrated Ecosystems: The Anatomy of a CHEMLYS Solution
Advanced Sampling & Interface Solutions
- Custom Sampling Plates: Engineered for seamless integration into your existing infrastructure.
- High-Performance membrane filters: Protecting your analyzer from particulates while maintaining flow consistency.
- Automated Multiposition Valves: For multi-stream monitoring and precise sample selection.
- Inert & Stainless Steel Tubing: Specialized treated tubes (e.g., Sulfinert/SilcoNert) to prevent the adsorption of reactive compounds.
- Precision Fittings & Connectors
Everything for a consistent analysis of your sample and the management of its constraints (Pressure, Temperature, Reactivity...).
Implementation
Our commitment concludes with personalized, hands-on training tailored to your industry’s requirements, ensuring your team achieves immediate operational proficiency and long-term analytical autonomy.
Scalable Configurations: Future-Proofing Your Investment
Module upgrades or sampling adaptations? Whatever your new process constraints, we partner with you to find the most sustainable and cost-effective solution, guaranteeing the longevity and relevance of your GC analyzers for years to come.
CHEMLYS is your guarantee of a seamless, turnkey installation, fully integrated into your specific research or industrial processes. Our dedicated specialists work side-by-side with you to ensure that every solution is meticulously engineered, validated, and tuned to exceed your operational expectations.
Analytical Reach: Solving Challenges in Every Sector

Energy & Fuels
Syngas analysis: Precision monitoring of H2, N2, CH4, CO, CO2. Detailed separation and quantification of C2 isomers—including ethylene, acetylene, and ethane—alongside linear C3 to C6 hydrocarbons.

Industrial Chemistry
Kinetics and breakthrough curves in Metal-Organic Frameworks Dual-module Micro GC for the simultaneous analysis of H2, O2, N2, CO2, C2-C6 hydrocarbons, and methanol.

Catalysis
Ammonia production (NH3): Dual-module Micro GC Fusion for the rapid monitoring of H2, N2, O2, N2O, CO2 and NH3 synthesis efficiency.

Petrochemistry and Refining
Refinery Gas Analysis (RGA): 3-module Micro GC for high-resolution profiling of H2, O2, N2, CH4, CO, CO2, C2-C6, C2 to C5 analysis.

Specialized Research & Academia
Electrolysis H2 production: Single-module Micro GC Fusion for real-time H2 purity and verification and O2, N2.